Search results

Search for "accelerating voltage" in Full Text gives 146 result(s) in Beilstein Journal of Nanotechnology.

Influence of conductive carbon and MnCo2O4 on morphological and electrical properties of hydrogels for electrochemical energy conversion

  • Sylwia Pawłowska,
  • Karolina Cysewska,
  • Yasamin Ziai,
  • Jakub Karczewski,
  • Piotr Jasiński and
  • Sebastian Molin

Beilstein J. Nanotechnol. 2024, 15, 57–70, doi:10.3762/bjnano.15.6

Graphical Abstract
  • an accelerating voltage of 10 kV. Before imaging, the hydrogel samples were freeze-dried and coated with a 10 nm gold layer. The chemical composition of the hydrogel was analysed with a Thermo Fisher Scientific silicon drift detector energy-dispersive X-ray spectroscope. For characterisation of the
PDF
Album
Supp Info
Full Research Paper
Published 11 Jan 2024

TEM sample preparation of lithographically patterned permalloy nanostructures on silicon nitride membranes

  • Joshua Williams,
  • Michael I. Faley,
  • Joseph Vimal Vas,
  • Peng-Han Lu and
  • Rafal E. Dunin-Borkowski

Beilstein J. Nanotechnol. 2024, 15, 1–12, doi:10.3762/bjnano.15.1

Graphical Abstract
  • techniques, a one-time exposure is possible with the help of high accelerating voltage during electron beam exposure. In this process, rather than doing one resist deposition and exposure after another, the layer selectivity is controlled by the electron beam dose and the sensitivity of the two layers. Only
PDF
Album
Supp Info
Full Research Paper
Published 02 Jan 2024

Isolation of cubic Si3P4 in the form of nanocrystals

  • Polina K. Nikiforova,
  • Sergei S. Bubenov,
  • Vadim B. Platonov,
  • Andrey S. Kumskov,
  • Nikolay N. Kononov,
  • Tatyana A. Kuznetsova and
  • Sergey G. Dorofeev

Beilstein J. Nanotechnol. 2023, 14, 971–979, doi:10.3762/bjnano.14.80

Graphical Abstract
  • , USA). TEM was carried out on a FEI Osiris microscope (Thermo Fisher Scientific, USA) at an accelerating voltage of 200 kV. Raman scattering of pellets of Si3P4 samples was obtained with an iRamanPlus (BW Tech) portable Raman spectrometer (532 nm laser). The integration time was 10 min, and eight
PDF
Album
Supp Info
Full Research Paper
Published 26 Sep 2023

Upscaling the urea method synthesis of CoAl layered double hydroxides

  • Camilo Jaramillo-Hernández,
  • Víctor Oestreicher,
  • Martín Mizrahi and
  • Gonzalo Abellán

Beilstein J. Nanotechnol. 2023, 14, 927–938, doi:10.3762/bjnano.14.76

Graphical Abstract
  • microscope at an accelerating voltage of 20 kV. Atomic force microscopy (AFM) AFM was carried out with a Bruker Dimension Icon microscope in scan-assist-mode. A Bruker Scanasyst-Air silicon tip with a diameter of around 10 nm was used to obtain images with a resolution of 512 × 512 or 1024 × 1024 pixels. The
  • Gwyddion software was used for flattening and image correction. Transmission electron microscopy (TEM) Transmission electron microscopy was carried out using a JEOL JEM-1010 at 100 kV accelerating voltage and a Tecnai F20 operated at 200 kV. Images were acquired in bright-field mode with an objective
PDF
Album
Supp Info
Full Research Paper
Published 11 Sep 2023

Carboxylic acids and light interact to affect nanoceria stability and dissolution in acidic aqueous environments

  • Matthew L. Hancock,
  • Eric A. Grulke and
  • Robert A. Yokel

Beilstein J. Nanotechnol. 2023, 14, 762–780, doi:10.3762/bjnano.14.63

Graphical Abstract
  • duration. The Thermo Scientific Talos F200X instrument equipped with a SuperX G2 EDS detector was operated at an accelerating voltage of 200 keV. The TEM images were recorded on a Ceta CCD camera. DLS was performed using a Brookhaven 90Plus particle size analyzer. Three analysis runs of 5 min each were
PDF
Album
Supp Info
Full Research Paper
Published 27 Jun 2023

Biocatalytic synthesis and ordered self-assembly of silica nanoparticles via a silica-binding peptide

  • Mustafa Gungormus

Beilstein J. Nanotechnol. 2023, 14, 280–290, doi:10.3762/bjnano.14.25

Graphical Abstract
  • ). All SEM analyses were performed using a SU5000 SEM (Hitachi, Japan) at 10 kV accelerating voltage. UV–vis absorbance spectroscopy The particles were assembled on quartz slides by vertical deposition as described before. UV–vis absorbance analysis was made using a T80+ UV–vis spectrophotometer (PG
PDF
Album
Supp Info
Full Research Paper
Published 28 Feb 2023

A novel approach to pulsed laser deposition of platinum catalyst on carbon particles for use in polymer electrolyte membrane fuel cells

  • Bogusław Budner,
  • Wojciech Tokarz,
  • Sławomir Dyjak,
  • Andrzej Czerwiński,
  • Bartosz Bartosewicz and
  • Bartłomiej Jankiewicz

Beilstein J. Nanotechnol. 2023, 14, 190–204, doi:10.3762/bjnano.14.19

Graphical Abstract
  • accelerating voltage of 20 kV and identical work parameters of the EDS detector. The quality of platinum coating on the carbon material was assessed based on images made using a transmission electron microscope (TEM) equipped with an energy-dispersive X-ray spectrometer (EDX). TEM measurements were carried out
PDF
Album
Supp Info
Full Research Paper
Published 02 Feb 2023

Two-step single-reactor synthesis of oleic acid- or undecylenic acid-stabilized magnetic nanoparticles by thermal decomposition

  • Mykhailo Nahorniak,
  • Pamela Pasetto,
  • Jean-Marc Greneche,
  • Volodymyr Samaryk,
  • Sandy Auguste,
  • Anthony Rousseau,
  • Nataliya Nosova and
  • Serhii Varvarenko

Beilstein J. Nanotechnol. 2023, 14, 11–22, doi:10.3762/bjnano.14.2

Graphical Abstract
  • an accelerating voltage of 200 kV was applied. The electronic diffraction patterns were obtained using the SAED technique. The XRD diffraction patterns were collected using a PANalytical MPD-PRO diffractometer equipped with a linear X’celerator detector and a Co Kα lamp as a source of radiation
PDF
Album
Supp Info
Full Research Paper
Published 03 Jan 2023

In search of cytotoxic selectivity on cancer cells with biogenically synthesized Ag/AgCl nanoparticles

  • Mitzi J. Ramírez-Hernández,
  • Mario Valera-Zaragoza,
  • Omar Viñas-Bravo,
  • Ariana A. Huerta-Heredia,
  • Miguel A. Peña-Rico,
  • Erick A. Juarez-Arellano,
  • David Paniagua-Vega,
  • Eduardo Ramírez-Vargas and
  • Saúl Sánchez-Valdes

Beilstein J. Nanotechnol. 2022, 13, 1505–1519, doi:10.3762/bjnano.13.124

Graphical Abstract
  • . Transmission electron microscopy images were acquired on a JEOL 1010 microscope, with an accelerating voltage of 80 kV. For that, samples were pre-prepared in acetone and sonicated for 20 min, then dried at room temperature. Thermogravimetric analysis was performed on a Perkin Elmer STA 6000 simultaneous
PDF
Album
Full Research Paper
Published 13 Dec 2022

Supramolecular assembly of pentamidine and polymeric cyclodextrin bimetallic core–shell nanoarchitectures

  • Alexandru-Milentie Hada,
  • Nina Burduja,
  • Marco Abbate,
  • Claudio Stagno,
  • Guy Caljon,
  • Louis Maes,
  • Nicola Micale,
  • Massimiliano Cordaro,
  • Angela Scala,
  • Antonino Mazzaglia and
  • Anna Piperno

Beilstein J. Nanotechnol. 2022, 13, 1361–1369, doi:10.3762/bjnano.13.112

Graphical Abstract
  • ultrapure water. The results are reported as the mean of three separate measurements ± the standard deviation (SD). The morphological characterization was performed using a high-resolution TecnaiG2 F20 XTWIN TEM with a 200 kV accelerating voltage. NMR spectra were recorded on a Varian 500 MHz spectrometer
PDF
Album
Supp Info
Full Research Paper
Published 18 Nov 2022

Effects of focused electron beam irradiation parameters on direct nanostructure formation on Ag surfaces

  • Jānis Sniķeris,
  • Vjačeslavs Gerbreders,
  • Andrejs Bulanovs and
  • Ēriks Sļedevskis

Beilstein J. Nanotechnol. 2022, 13, 1004–1010, doi:10.3762/bjnano.13.87

Graphical Abstract
  • changed while the other parameters were kept constant. The accelerating voltage U was equal to 30 kV in all experiments and the angle of incidence α was equal to 0°, unless stated otherwise. Following irradiation, the height and volume of the structures formed in irradiated points were determined by non
PDF
Album
Full Research Paper
Published 22 Sep 2022

Interaction between honeybee mandibles and propolis

  • Leonie Saccardi,
  • Franz Brümmer,
  • Jonas Schiebl,
  • Oliver Schwarz,
  • Alexander Kovalev and
  • Stanislav Gorb

Beilstein J. Nanotechnol. 2022, 13, 958–974, doi:10.3762/bjnano.13.84

Graphical Abstract
  • studied using a SEM (Hitachi S-4800, Hitachi High-Technologies Corp., Tokyo, Japan) at 3 kV accelerating voltage. Images of the spoon-shaped mandible tip were taken systematically and later assembled into one high resolution image. Higher magnified pictures were taken in characteristic areas of the
  • (Hitachi S-4800, Hitachi High-Technologies Corp., Tokyo, Japan) equipped with a cryopreparation system (Gatan ALTO 2500, Gatan, Inc., Abingdon, UK) at 3 kV accelerating voltage. Image processing SEM images were processed using Gimp, version 2.10.14. All adjustments were applied to the whole image. Color
PDF
Album
Full Research Paper
Published 14 Sep 2022

Hierachical epicuticular wax coverage on leaves of Deschampsia antarctica as a possible adaptation to severe environmental conditions

  • Elena V. Gorb,
  • Iryna A. Kozeretska and
  • Stanislav N. Gorb

Beilstein J. Nanotechnol. 2022, 13, 807–816, doi:10.3762/bjnano.13.71

Graphical Abstract
  • (Hitachi High-Technologies Corporation, Tokyo, Japan) at 3 kV accelerating voltage. Description of trichomes was performed according to [14]. Types of epicuticular wax structures were identified according to [15]. Morphometric variables of surface features were measured from digital images using the
PDF
Album
Full Research Paper
Published 22 Aug 2022

Detection and imaging of Hg(II) in vivo using glutathione-functionalized gold nanoparticles

  • Gufeng Li,
  • Shaoqing Li,
  • Rui Wang,
  • Min Yang,
  • Lizhu Zhang,
  • Yanli Zhang,
  • Wenrong Yang and
  • Hongbin Wang

Beilstein J. Nanotechnol. 2022, 13, 549–559, doi:10.3762/bjnano.13.46

Graphical Abstract
  • were of analytical grade. TEM was carried out using a JEM-2100 transmission electron microscope (JEOL, Japan) at an accelerating voltage of 200 kV. UV–vis absorption spectra were obtained using a UV-2100 Spectrophotometer (Shimadzu, Japan). Fluorescence spectra were recorded using an F-7000
PDF
Album
Supp Info
Full Research Paper
Published 23 Jun 2022

Enhancement of the piezoelectric coefficient in PVDF-TrFe/CoFe2O4 nanocomposites through DC magnetic poling

  • Marco Fortunato,
  • Alessio Tamburrano,
  • Maria Paola Bracciale,
  • Maria Laura Santarelli and
  • Maria Sabrina Sarto

Beilstein J. Nanotechnol. 2021, 12, 1262–1270, doi:10.3762/bjnano.12.93

Graphical Abstract
  • °C and a DC magnetic field was applied through a ferromagnetic core (Figure 8). The morphology of the PVDF-TrFe/CoFe2O4 nanocomposite thin films was investigated using a field-emission scanning electron microscope (FESEM, Auriga, Carl Zeiss) operated with an accelerating voltage of 5 kV. Chemical
PDF
Album
Full Research Paper
Published 19 Nov 2021

High-yield synthesis of silver nanowires for transparent conducting PET films

  • Gul Naz,
  • Hafsa Asghar,
  • Muhammad Ramzan,
  • Muhammad Arshad,
  • Rashid Ahmed,
  • Muhammad Bilal Tahir,
  • Bakhtiar Ul Haq,
  • Nadeem Baig and
  • Junaid Jalil

Beilstein J. Nanotechnol. 2021, 12, 624–632, doi:10.3762/bjnano.12.51

Graphical Abstract
  • operated at an accelerating voltage of 10 kV and ZEISS SEM operated at an accelerating voltage of 20 kV) were utilized. Luminescence measurements were carried out by using a Cary Eclipse MY18060003 photoluminescence spectrometer in the wavelength range of 400–700 nm while exciting the sample at 300 nm
PDF
Album
Full Research Paper
Published 01 Jul 2021

The preparation temperature influences the physicochemical nature and activity of nanoceria

  • Robert A. Yokel,
  • Wendel Wohlleben,
  • Johannes Georg Keller,
  • Matthew L. Hancock,
  • Jason M. Unrine,
  • D. Allan Butterfield and
  • Eric A. Grulke

Beilstein J. Nanotechnol. 2021, 12, 525–540, doi:10.3762/bjnano.12.43

Graphical Abstract
  • approximately 5 s and dried overnight at room temperature. Electron microscopy was performed on a Thermo Scientific Talos F200X operated at an accelerating voltage of 200 keV. Images were recorded with a Ceta CCD camera. The mean and Feret diameters and area, and their standard deviation, minimum, and maximum
PDF
Album
Supp Info
Full Research Paper
Published 04 Jun 2021

Boosting of photocatalytic hydrogen evolution via chlorine doping of polymeric carbon nitride

  • Malgorzata Aleksandrzak,
  • Michalina Kijaczko,
  • Wojciech Kukulka,
  • Daria Baranowska,
  • Martyna Baca,
  • Beata Zielinska and
  • Ewa Mijowska

Beilstein J. Nanotechnol. 2021, 12, 473–484, doi:10.3762/bjnano.12.38

Graphical Abstract
  • using TEM (Tecnai F30) with an accelerating voltage of 200 kV. The FTIR spectra were recorded on a Nicolet 6700 FT-IR spectrometer. The chemical composition and relative atomic percentages on the surface of the samples were studied by XPS. The measurements were conducted using Mg Kα (hν = 1253.6 eV
PDF
Album
Full Research Paper
Published 19 May 2021

Nickel nanoparticle-decorated reduced graphene oxide/WO3 nanocomposite – a promising candidate for gas sensing

  • Ilka Simon,
  • Alexandr Savitsky,
  • Rolf Mülhaupt,
  • Vladimir Pankov and
  • Christoph Janiak

Beilstein J. Nanotechnol. 2021, 12, 343–353, doi:10.3762/bjnano.12.28

Graphical Abstract
  • diluted 1:100. Transmission electron microscopy, TEM was performed with a FEI Tecnai G2 F20 electron microscope [68] operated at 200 kV accelerating voltage or FEI Titan 80-300 TEM operated at 300 kV accelerating voltage [69]. Conventional TEM images were recorded with a Gatan UltraScan 1000P detector
PDF
Album
Supp Info
Full Research Paper
Published 15 Apr 2021

Magnetic-field-assisted synthesis of anisotropic iron oxide particles: Effect of pH

  • Andrey V. Shibaev,
  • Petr V. Shvets,
  • Darya E. Kessel,
  • Roman A. Kamyshinsky,
  • Anton S. Orekhov,
  • Sergey S. Abramchuk,
  • Alexei R. Khokhlov and
  • Olga E. Philippova

Beilstein J. Nanotechnol. 2020, 11, 1230–1241, doi:10.3762/bjnano.11.107

Graphical Abstract
  • (LEO/Carl Zeiss, Germany) at an accelerating voltage of 100 kV. The reference diffraction pattern of magnetite was obtained from commercially available nanoparticles (ABCR, product number AB304117) with a diameter range of 20–50 nm. Details of the TEM experimental procedures were described elsewhere
PDF
Album
Supp Info
Full Research Paper
Published 17 Aug 2020

A set of empirical equations describing the observed colours of metal–anodic aluminium oxide–Al nanostructures

  • Cristina V. Manzano,
  • Jakob J. Schwiedrzik,
  • Gerhard Bürki,
  • Laszlo Pethö,
  • Johann Michler and
  • Laetitia Philippe

Beilstein J. Nanotechnol. 2020, 11, 798–806, doi:10.3762/bjnano.11.64

Graphical Abstract
  • . After that, the Cr layer was deposited. Characterization of AAO films Morphological characterisation was performed using a field-emission scanning electron microscope (FESEM, Hitachi S-4800) with a 1.5 kV accelerating voltage. The thickness was obtained from sample cross sections fabricated using a
PDF
Album
Supp Info
Full Research Paper
Published 13 May 2020

Nickel nanoparticles supported on a covalent triazine framework as electrocatalyst for oxygen evolution reaction and oxygen reduction reactions

  • Secil Öztürk,
  • Yu-Xuan Xiao,
  • Dennis Dietrich,
  • Beatriz Giesen,
  • Juri Barthel,
  • Jie Ying,
  • Xiao-Yu Yang and
  • Christoph Janiak

Beilstein J. Nanotechnol. 2020, 11, 770–781, doi:10.3762/bjnano.11.62

Graphical Abstract
  • was washed off three times with acetonitrile and left to dry. Images were recorded on a FEI Tecnai G2 F20 electron microscope operated at 200 kV accelerating voltage equipped with a Gatan UltraScan 1000P detector [68]. Scanning transmission electron microscopy (STEM) images and EDX elemental mapping
  • were conducted with the same instrument. High-resolution TEM images were recorded with an FEI Titan 80-300 transmission electron microscope [69] operated at 300 kV accelerating voltage. The microscope is equipped with an image CS corrector and a 2k × 2k GATAN UltraScan 1000 CCD. Nanoparticle size and
PDF
Album
Supp Info
Full Research Paper
Published 11 May 2020

Preparation and in vivo evaluation of glyco-gold nanoparticles carrying synthetic mycobacterial hexaarabinofuranoside

  • Gennady L. Burygin,
  • Polina I. Abronina,
  • Nikita M. Podvalnyy,
  • Sergey A. Staroverov,
  • Leonid O. Kononov and
  • Lev A. Dykman

Beilstein J. Nanotechnol. 2020, 11, 480–493, doi:10.3762/bjnano.11.39

Graphical Abstract
  • electron microscopy Glyco-GNPs 3 and 4 were characterized using a Libra 120 transmission electron microscope (Carl Zeiss, Germany) at 120 kV accelerating voltage at the "Simbioz" Center for the Collective Use of the Research Equipment in the Field of Physical-Chemical Biology and Nanobiotechnology at the
PDF
Album
Supp Info
Full Research Paper
Published 19 Mar 2020

Nanoparticles based on the zwitterionic pillar[5]arene and Ag+: synthesis, self-assembly and cytotoxicity in the human lung cancer cell line A549

  • Dmitriy N. Shurpik,
  • Denis A. Sevastyanov,
  • Pavel V. Zelenikhin,
  • Pavel L. Padnya,
  • Vladimir G. Evtugyn,
  • Yuriy N. Osin and
  • Ivan I. Stoikov

Beilstein J. Nanotechnol. 2020, 11, 421–431, doi:10.3762/bjnano.11.33

Graphical Abstract
  • held at the accelerating voltage of 80 kV in scanning TEM mode using an Oxford Instruments X-Maxn 80T EDS detector. In vitro cell viability The characterization of the A549 cell viability changes under the pillar[5]arenes 3 and 4 action was performed by the MTT assay. A cell suspension of 150 μL/well
PDF
Album
Supp Info
Full Research Paper
Published 05 Mar 2020

Formation of nanoripples on ZnO flat substrates and nanorods by gas cluster ion bombardment

  • Xiaomei Zeng,
  • Vasiliy Pelenovich,
  • Bin Xing,
  • Rakhim Rakhimov,
  • Wenbin Zuo,
  • Alexander Tolstogouzov,
  • Chuansheng Liu,
  • Dejun Fu and
  • Xiangheng Xiao

Beilstein J. Nanotechnol. 2020, 11, 383–390, doi:10.3762/bjnano.11.29

Graphical Abstract
  • used to irradiate single crystal ZnO substrates and nanorods to fabricate self-assembled surface nanoripple arrays. The ripple formation is observed when the incidence angle of the cluster beam is in the range of 30–70°. The influence of incidence angle, accelerating voltage, and fluence on the ripple
  • formation is studied. Wavelength and height of the nanoripples increase with increasing accelerating voltage and fluence for both targets. The nanoripples formed on the flat substrates remind of aeolian sand ripples. The ripples formed at high ion fluences on the nanorod facets resemble well-ordered
  • bombardment, the modified surface morphology of the flat substrates and nanorods was studied with a scanning electron microscope (SEM) Zeiss Sigma, operated at 20 kV accelerating voltage. An atomic force microscope (AFM) Shimadzu SPM-9500J3 was used to study the ripple formation on the flat ZnO substrates
PDF
Album
Full Research Paper
Published 24 Feb 2020
Other Beilstein-Institut Open Science Activities